{"id":2004,"date":"2026-08-19T07:13:29","date_gmt":"2026-08-19T07:13:29","guid":{"rendered":"https:\/\/www.bimdex.com\/blogs\/?p=2004"},"modified":"2026-08-19T07:13:47","modified_gmt":"2026-08-19T07:13:47","slug":"why-generic-file-formats-like-step-and-ifc-holding-back-water-infrastructure-design","status":"publish","type":"post","link":"https:\/\/www.bimdex.com\/blogs\/why-generic-file-formats-like-step-and-ifc-holding-back-water-infrastructure-design\/","title":{"rendered":"Why Generic File Formats (Like STEP and IFC) Holding Back Water Infrastructure Design"},"content":{"rendered":"<p><span data-contrast=\"none\">The digital transformation across the industries has enforced the\u00a0demography\u00a0to adopt\u00a0serious changes\u00a0that\u00a0impact\u00a0the overall workflow, leading to improved\u00a0processes.\u00a0Water infrastructure like wastewater industries, drinking water networks, and huge pump stations\u00a0come\u00a0under such industries that are slowly\u00a0transforming in digital aspects, that includes creating designs and exchanging them across software applications.<\/span><span data-ccp-props=\"{&quot;335551550&quot;:6,&quot;335551620&quot;:6}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"none\">Being an industry of enormous design and associated data,\u00a0water\u00a0demography demands a superior medium of data\u00a0translation\u00a0where every specific information is captured\u00a0and transferred.\u00a0Water industry engineers are experiencing frustrating battles with the software and the exchange process as the data gets distorted at various instances.<\/span><span data-ccp-props=\"{&quot;335551550&quot;:6,&quot;335551620&quot;:6}\">\u00a0<\/span><\/p>\n<p><a href=\"https:\/\/www.bimdex.com\/blogs\/bxf-vs-ifc-vs-step-comparing-data-exchange-formats-for-better-collaboration\/\"><span data-contrast=\"none\">Generic file formats like STEP and\u00a0IFC<\/span><\/a><span data-contrast=\"none\">\u00a0are eventually rupturing the data, leaving residues\u00a0often,\u00a0and they are holding back the water infrastructure design\u00a0unfortunately. In this blog, we shall understand why the generic formats fail and how an interoperable model exchange medium\u00a0like\u00a0BIMDeX\u00a0enhances\u00a0the process\u00a0industry\u00a0purpose.<\/span><span data-ccp-props=\"{&quot;335551550&quot;:6,&quot;335551620&quot;:6}\">\u00a0<\/span><\/p>\n<h2 aria-level=\"2\"><span class=\"ez-toc-section\" id=\"The_Generic_File_Formats_%E2%80%93_STEP_and_IFC\"><\/span><span data-contrast=\"none\">The Generic File Formats \u2013 STEP and IFC<\/span><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:160,&quot;335559739&quot;:80}\">\u00a0<\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span data-contrast=\"none\">Firstly, it is important to understand that the generic file formats\u00a0aren\u2019t\u00a0bad; they are\u00a0misapplied\u00a0with the existing industries and the demography.\u00a0Though the formats serve a huge purpose, they lack compatibility with the digital aspects which are the data carrying bridge nowadays.<\/span><span data-ccp-props=\"{&quot;335551550&quot;:6,&quot;335551620&quot;:6}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"none\">Before addressing the limitations, we shall explore the\u00a0magnificence\u00a0that the\u00a0formats hold and are serving the realm for decades.<\/span><span data-ccp-props=\"{&quot;335551550&quot;:6,&quot;335551620&quot;:6}\">\u00a0<\/span><\/p>\n<h2 aria-level=\"3\"><span class=\"ez-toc-section\" id=\"STEP_Format\"><\/span><span data-contrast=\"none\">STEP Format<\/span><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:160,&quot;335559739&quot;:80}\">\u00a0<\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span data-contrast=\"auto\">STEP format has been the reliable format that the users prefer for manufacturing and mechanical domains.\u00a0STEP files serve several benefits while converting\u00a0highly complex\u00a0equipment\u00a0models like huge water pressure\u00a0pumps\u00a0and turbines.<\/span><span data-ccp-props=\"{&quot;335551550&quot;:6,&quot;335551620&quot;:6}\">\u00a0<\/span><\/p>\n<p><i><span data-contrast=\"auto\">How\u00a0excellent they are!<\/span><\/i><span data-ccp-props=\"{&quot;335551550&quot;:6,&quot;335551620&quot;:6}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">Despite being a primitive file format,\u00a0<\/span><a href=\"https:\/\/www.bimdex.com\/ecosystem\/ifc-exporter.php\"><span data-contrast=\"none\">STEP format<\/span><\/a><span data-contrast=\"auto\">\u00a0has been playing a predominant role\u00a0as a breakthrough to interconnect mechanical and product design.<\/span><span data-ccp-props=\"{&quot;335551550&quot;:6,&quot;335551620&quot;:6}\">\u00a0<\/span><\/p>\n<ul>\n<li aria-setsize=\"-1\" data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"2\" data-list-defn-props=\"{&quot;335552541&quot;:1,&quot;335559685&quot;:720,&quot;335559991&quot;:360,&quot;469769226&quot;:&quot;Symbol&quot;,&quot;469769242&quot;:[8226],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;\uf0b7&quot;,&quot;469777815&quot;:&quot;hybridMultilevel&quot;}\" data-aria-posinset=\"1\" data-aria-level=\"1\"><span data-contrast=\"auto\">STEP files are exceptionally perfect in mathematical equations to\u00a0describe shapes during exchange<\/span><span data-ccp-props=\"{&quot;335551550&quot;:6,&quot;335551620&quot;:6}\">\u00a0<\/span><\/li>\n<\/ul>\n<ul>\n<li aria-setsize=\"-1\" data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"2\" data-list-defn-props=\"{&quot;335552541&quot;:1,&quot;335559685&quot;:720,&quot;335559991&quot;:360,&quot;469769226&quot;:&quot;Symbol&quot;,&quot;469769242&quot;:[8226],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;\uf0b7&quot;,&quot;469777815&quot;:&quot;hybridMultilevel&quot;}\" data-aria-posinset=\"2\" data-aria-level=\"1\"><span data-contrast=\"auto\">STEP files\u00a0serve\u00a0as unified data set to transfer geometric data between applications\u00a0and\u00a0initiate\u00a0real data conversion\u00a0which earlier sought after costly intermediate vendors<\/span><span data-ccp-props=\"{&quot;335551550&quot;:6,&quot;335551620&quot;:6}\">\u00a0<\/span><\/li>\n<\/ul>\n<ul>\n<li aria-setsize=\"-1\" data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"2\" data-list-defn-props=\"{&quot;335552541&quot;:1,&quot;335559685&quot;:720,&quot;335559991&quot;:360,&quot;469769226&quot;:&quot;Symbol&quot;,&quot;469769242&quot;:[8226],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;\uf0b7&quot;,&quot;469777815&quot;:&quot;hybridMultilevel&quot;}\" data-aria-posinset=\"3\" data-aria-level=\"1\"><span data-contrast=\"auto\">STEP protocols make sure to\u00a0preserve the assembly and\u00a0transfer the hierarchy as it is without\u00a0flattening and\u00a0maintaining\u00a0the parent-child relationship intact after conversion.<\/span><span data-ccp-props=\"{&quot;335551550&quot;:6,&quot;335551620&quot;:6}\">\u00a0<\/span><\/li>\n<\/ul>\n<h2 aria-level=\"3\"><span class=\"ez-toc-section\" id=\"IFC_Format\"><\/span><span data-contrast=\"none\">IFC Format<\/span><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:160,&quot;335559739&quot;:80}\">\u00a0<\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span data-contrast=\"auto\">Another reliable format with excellent ability is IFC. It is an open-standard and vendor-neutral format built to connect\u00a0architects, engineers, and contractors to share 3D models and the associated data.\u00a0This format holds prominence in\u00a0assisting\u00a0comprehensive asset management and BIM collaboration.<\/span><span data-ccp-props=\"{&quot;335551550&quot;:6,&quot;335551620&quot;:6}\">\u00a0<\/span><\/p>\n<p><i><span data-contrast=\"auto\">How\u00a0excellent they are!<\/span><\/i><span data-ccp-props=\"{&quot;335551550&quot;:6,&quot;335551620&quot;:6}\">\u00a0<\/span><\/p>\n<ul>\n<li aria-setsize=\"-1\" data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"1\" data-list-defn-props=\"{&quot;335552541&quot;:1,&quot;335559685&quot;:720,&quot;335559991&quot;:360,&quot;469769226&quot;:&quot;Symbol&quot;,&quot;469769242&quot;:[8226],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;\uf0b7&quot;,&quot;469777815&quot;:&quot;hybridMultilevel&quot;}\" data-aria-posinset=\"1\" data-aria-level=\"1\"><span data-contrast=\"auto\">IFC is known for semantic intelligence as it defines the objects or the shapes with a context.\u00a0The\u00a0software understands the IFC models and easily defines the shapes as wall, pump, or window.<\/span><span data-ccp-props=\"{&quot;335551550&quot;:6,&quot;335551620&quot;:6}\">\u00a0<\/span><\/li>\n<\/ul>\n<ul>\n<li aria-setsize=\"-1\" data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"1\" data-list-defn-props=\"{&quot;335552541&quot;:1,&quot;335559685&quot;:720,&quot;335559991&quot;:360,&quot;469769226&quot;:&quot;Symbol&quot;,&quot;469769242&quot;:[8226],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;\uf0b7&quot;,&quot;469777815&quot;:&quot;hybridMultilevel&quot;}\" data-aria-posinset=\"2\" data-aria-level=\"1\"><span data-contrast=\"auto\">The open BIM standard of the file offers\u00a0unified\u00a0data for the professionals to collaborate with work even if they use different software vendors.<\/span><span data-ccp-props=\"{&quot;335551550&quot;:6,&quot;335551620&quot;:6}\">\u00a0<\/span><\/li>\n<\/ul>\n<ul>\n<li aria-setsize=\"-1\" data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"1\" data-list-defn-props=\"{&quot;335552541&quot;:1,&quot;335559685&quot;:720,&quot;335559991&quot;:360,&quot;469769226&quot;:&quot;Symbol&quot;,&quot;469769242&quot;:[8226],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;\uf0b7&quot;,&quot;469777815&quot;:&quot;hybridMultilevel&quot;}\" data-aria-posinset=\"3\" data-aria-level=\"1\"><span data-contrast=\"auto\">Since IFC is open standard and true, professionals can access the information even after decades and this avoids\u00a0obsolescence.\u00a0<\/span><span data-ccp-props=\"{&quot;335551550&quot;:6,&quot;335551620&quot;:6}\">\u00a0<\/span><\/li>\n<\/ul>\n<h3 aria-level=\"2\"><span data-contrast=\"none\">Why generic file formats fail<\/span><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:160,&quot;335559739&quot;:80}\">\u00a0<\/span><\/h3>\n<p><span data-contrast=\"auto\">Though the STEP and IFC (generic formats)\u00a0have\u00a0been\u00a0pivotal players\u00a0in data exchange, they lack efficiency\u00a0when it comes to\u00a0water industry-based data exchange. As we know already, the water industry does not\u00a0comprise\u00a0just\u00a0static 3D\u00a0shapes;\u00a0instead,\u00a0it is filled with complex\u00a0and dynamic interconnected systems, that\u00a0include\u00a0fluid dynamics and chemical pipelines and forces.<\/span><span data-ccp-props=\"{&quot;335551550&quot;:6,&quot;335551620&quot;:6}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">With this situation said, generic file formats like STEP and IFC cannot compensate for a credible data conversion, as it might strip the organic information and take only the mere 3D geometry.<\/span><span data-ccp-props=\"{&quot;335551550&quot;:6,&quot;335551620&quot;:6}\">\u00a0<\/span><\/p>\n<h3 aria-level=\"3\"><span data-contrast=\"none\">Geometry Bottleneck<\/span><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:160,&quot;335559739&quot;:80}\">\u00a0<\/span><\/h3>\n<p><span data-contrast=\"auto\">STEP file is a geometry dominant format that concentrates\u00a0translating\u00a0geometric information with utmost precision.\u00a0But\u00a0the water\u00a0industry,\u00a0which is beyond static\u00a0buildings,\u00a0requires more.\u00a0<\/span><span data-ccp-props=\"{&quot;335551550&quot;:6,&quot;335551620&quot;:6}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">STEP file works best for\u00a0mechanical\u00a0and aerospace engineering, and when a water industry professional exports a pumping station,\u00a0STEP file\u00a0understands the curvature and transfers the\u00a0accurate\u00a0geometry but cannot understand what the\u00a0component\u00a0is and the usage. When this\u00a0happens,\u00a0the parametric objects are\u00a0stripped\u00a0and only\u00a0dumb\u00a03D geometry is transferred.<\/span><span data-ccp-props=\"{&quot;335551550&quot;:6,&quot;335551620&quot;:6}\">\u00a0<\/span><\/p>\n<h3 aria-level=\"3\"><span data-contrast=\"none\">Connection Limitations<\/span><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:160,&quot;335559739&quot;:80}\">\u00a0<\/span><\/h3>\n<p><span data-contrast=\"auto\">It is well known that water infrastructure is filled with relationships; having said about IFC, the format defines the objects in infrastructure like\u00a0walls\u00a0and windows, but for this industry its ability is not sufficient.<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">IFC fundamentally breaks down when it\u00a0comes to\u00a0linear water connection, as it cannot preserve the topology, and the logical connections between objects.\u00a0When a series of pipe connections are transferred as an IFC file, the connection breaks and is exported as separate cylinders.<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">Inefficiency\u00a0can lead to loss of prominent engineering parameters and leads to the loss of embedded data. This\u00a0comprehensive\u00a0loss can force the engineers to rebuild everything manually\u00a0and network logic from the\u00a0initial\u00a0point.<\/span><span data-ccp-props=\"{&quot;335551550&quot;:6,&quot;335551620&quot;:6}\">\u00a0<\/span><\/p>\n<h3 aria-level=\"3\"><span data-contrast=\"none\">Digital Twin Inefficiency<\/span><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:160,&quot;335559739&quot;:80}\">\u00a0<\/span><\/h3>\n<p><span data-contrast=\"auto\">With every\u00a0project\u00a0moving its interest towards digital twin,\u00a0water industry demands the update as the rupturing infrastructure requires\u00a0advanced stations,\u00a0buildings\u00a0and\u00a0virtual representation\u00a0of the structures\u00a0to have extended lifecycle management.<\/span><span data-ccp-props=\"{&quot;335551550&quot;:6,&quot;335551620&quot;:6}\">\u00a0<\/span><\/p>\n<p>Unfortunately, the generic file formats do not suit and stand as a barrier for digital twin aspect for the water industry. Since STEP and IFC strip the <a href=\"https:\/\/www.bimdex.com\/blogs\/how-to-maintain-data-integrity-when-exchanging-cad-files\/\">parametric information<\/a> and component metadata, it leaves only exports hollow mere 3D geometry. The team cannot extract the essential information from static geometry, and this takes the process to scratch where experts have to spend more time and cost in adding component metadata.<\/p>\n<h3 aria-level=\"3\"><span data-contrast=\"none\">Collaborative limitations and huge file size<\/span><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:160,&quot;335559739&quot;:80}\">\u00a0<\/span><\/h3>\n<p><span data-contrast=\"auto\">Since the generic file formats cannot transfer\u00a0parametric\u00a0information, they intend to define each shape like the polygon,\u00a0face,\u00a0and 3D\u00a0model\u00a0vertex.\u00a0Water infrastructure like the water treatment plant will have thousands of pipes, valves, edges, connectors and more; defining each component eventually increases the file size.<\/span><span data-ccp-props=\"{&quot;335551550&quot;:6,&quot;335551620&quot;:6}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">Exporting such a huge file with vast information, retards the process, puts collaboration at\u00a0stake\u00a0and corrupts the file at last.<\/span><span data-ccp-props=\"{&quot;335551550&quot;:6,&quot;335551620&quot;:6}\">\u00a0<\/span><\/p>\n<h3 aria-level=\"2\"><span data-contrast=\"none\">BIMDeX\u00a0\u2013 Essential Remedy<\/span><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:160,&quot;335559739&quot;:80}\">\u00a0<\/span><\/h3>\n<p>Generic file formats rip parametric information despite being interoperable, certain middleware is high in cost and requires manual rework at certain instance; this is the situation that the water industry stays in. How about an interoperable solution that can promise ideal model conversion for the water industry, while preserving metadata, parametric information, automatically categorize components, simplify huge models into lightweight models, preserve coordinates, maintain hierarchy, <a href=\"https:\/\/www.bimdex.com\/dx-integration.php\">cloud-based integration<\/a> and a lot more?<\/p>\n<p><span data-contrast=\"auto\">BIMDeX\u00a0is one such\u00a0ideal solution to deploy\u00a0interoperable model conversion between applications while preserving the asset metadata. The\u00a0<\/span><a href=\"https:\/\/www.bimdex.com\/bxf-manager.php\"><span data-contrast=\"none\">proprietary file format called BXF<\/span><\/a><span data-contrast=\"auto\">\u00a0works unlike other proprietary formats as it stands compatible with various software applications where the\u00a0BIMDeX\u00a0plugin is installed.<\/span><span data-ccp-props=\"{&quot;335551550&quot;:6,&quot;335551620&quot;:6}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">The increasing demand of the water industry needs an application that streamlines the workflow beyond just model conversion.\u00a0Get in touch with\u00a0BIMDeX\u00a0and get to know more.<\/span><span data-ccp-props=\"{&quot;335551550&quot;:6,&quot;335551620&quot;:6}\">\u00a0<\/span><\/p>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_73 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.bimdex.com\/blogs\/why-generic-file-formats-like-step-and-ifc-holding-back-water-infrastructure-design\/#The_Generic_File_Formats_%E2%80%93_STEP_and_IFC\" title=\"The Generic File Formats \u2013 STEP and IFC\u00a0\">The Generic File Formats \u2013 STEP and IFC\u00a0<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.bimdex.com\/blogs\/why-generic-file-formats-like-step-and-ifc-holding-back-water-infrastructure-design\/#STEP_Format\" title=\"STEP Format\u00a0\">STEP Format\u00a0<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.bimdex.com\/blogs\/why-generic-file-formats-like-step-and-ifc-holding-back-water-infrastructure-design\/#IFC_Format\" title=\"IFC Format\u00a0\">IFC Format\u00a0<\/a><\/li><\/ul><\/nav><\/div>\n","protected":false},"excerpt":{"rendered":"<p>The digital transformation across the industries has enforced the\u00a0demography\u00a0to adopt\u00a0serious changes\u00a0that\u00a0impact\u00a0the overall workflow, leading to improved\u00a0processes.\u00a0Water infrastructure like wastewater industries, drinking water networks, and huge pump stations\u00a0come\u00a0under such industries that are slowly\u00a0transforming in digital aspects, that includes creating designs and exchanging them across software applications.\u00a0 Being an industry of enormous design and associated data,\u00a0water\u00a0demography demands &hellip;<\/p>\n","protected":false},"author":8,"featured_media":2005,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[10],"tags":[],"class_list":["post-2004","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bim"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.bimdex.com\/blogs\/wp-json\/wp\/v2\/posts\/2004","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bimdex.com\/blogs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bimdex.com\/blogs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bimdex.com\/blogs\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bimdex.com\/blogs\/wp-json\/wp\/v2\/comments?post=2004"}],"version-history":[{"count":1,"href":"https:\/\/www.bimdex.com\/blogs\/wp-json\/wp\/v2\/posts\/2004\/revisions"}],"predecessor-version":[{"id":2006,"href":"https:\/\/www.bimdex.com\/blogs\/wp-json\/wp\/v2\/posts\/2004\/revisions\/2006"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bimdex.com\/blogs\/wp-json\/wp\/v2\/media\/2005"}],"wp:attachment":[{"href":"https:\/\/www.bimdex.com\/blogs\/wp-json\/wp\/v2\/media?parent=2004"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bimdex.com\/blogs\/wp-json\/wp\/v2\/categories?post=2004"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bimdex.com\/blogs\/wp-json\/wp\/v2\/tags?post=2004"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}